Corrosion Inhibitor Aid 90% (Formic Acid)

Corrosion Inhibitor Aid 90% (Formic Acid)

ZX-C1-06 is an excellent bland of organic liquid specially designed corrosion inhibitors, surface active agent in solvent. It is designed to absorb or form a protective film on the metal surface.
Send Inquiry
Description
General

 

General

 

ZX-C1-06 corrosion inhibitor aid is an excellent bland of organic liquid specially designed corrosion inhibitors, surface active agent in solvent. It is designed to absorb or form a protective film on the metal surface.

It can be used to inhibit the attack of various acids on metal during the scaling of equipment and it is also used during acidulation of oil well to protect tubing&other.

 

Product Properties

 

Color                                     Clear liquid

Flash point                           62 ℃

PH (1% aqueous solution)  2-5

Specific Gravity                   1.100~1.250

Solubility                              Soluble in water

 

Application

 

Field of application

ZX-C1-06 corrosion inhibitor aid is effective in all HCl solutions and Brine Solution. It can be used by Hydrochloric Acid with Acetic Acid, Formic Acid & Hydrofluoric Acid. It provides corrosion protection of tubular and down hold production equipment.

 

Packing

200L steel drums or 1000L IBC or per clients' request

Storage

ZX-C1-06 corrosion inhibitor aid hould be stored in closed containers in a dry environment. The expiry date is 2 years from production date and can be extended for extra 1 year after a successful testing of the physical and chemical index.

 

Safety and handling

 

Skin Exposure:

In case of contact, immediately wash skin with soap and copious amounts of water. If irritation persists, call a physician.

Eye Exposure:

In case of contact with eyes, flush with copious amounts of water for at least 15 minutes. Assure adequate flushing by separating the eyelids with fingers.

If irritation persists, call a physician.

Inhalation Exposure:

If inhaled, remove to fresh air. If necessary, give oxygen. Call a physician.

Oral Exposure:

If swallowed, immediately wash out mouth with water provided person is conscious. Call a physician.

Hot Tags: corrosion inhibitor aid 90% (formic acid), China corrosion inhibitor aid 90% (formic acid) manufacturers, suppliers, factory, corrosion inhibitor for extreme conditions, mixed corrosion inhibitor, certified corrosion inhibitor, corrosion inhibitor for actuators, corrosion inhibitor for semiconductor manufacturing, standard corrosion inhibitor