General
ZX-C1-04 Acid Corrosion Inhibitor 140℃ is composed of home-grown composite pyridine quaternary ammonium salts main ingredients, some alkynol and aldehydes material. It has good dispersibility in HCl and mud acid. It has a good corrosion protective effect on HCl and mud acid corrosion under high temperature. The effect of high temperature resistant is good.
Composition
Composite pyridine quaternary ammonium salts, alkynol and aldehyde material
Product properties
|
Appearance Reddish brown liquid
Density 0.95-1.03 (g/cm3, 20℃)
Freezing point <= -15 ℃
PH (1% aqueous solution) 3.0 - 5.0
Corrosion rate 10-15 (g/m2.h, 120℃)
Corrosion rate 20~30 (g/m2.h, 140℃)
|
Application
Site Application
Acid corrosion inhibitor ZX-C1-04 is applicable for oil well high temperature and acidizing fracturing technology to control equipment corrosion. It has a good effect on deep oil well high temperature, high pressure acidizing corrosion control in the high temperature range of 120~140℃, in 15~20% HCl and mud acid.
Test condition
120℃ test conditions: Dynamic, 16Mpa, 15% HCl or N80 steel, 4h, 2% addition
140℃ test conditions: Dynamic, 16Mpa, 15% HCl or N80 steel, 4h, 3% addition
Classification by temperature :
High-temperature type (160-210℃) : such as YTY-10, F2146, with a corrosion inhibition rate exceeding 98%.
Medium and low temperature type: Contains imidazoline (IS-129) and organic amine (ET-105).
Product characteristic
Applicable for 120-140℃ high temperature acidizing system and high temperature resistance.
Good compatibility with thickener and crosslinker
Storage
ZX-C1-04 Acid Corrosion Inhibitor 140℃ should be stored in closed containers in a dry environment. The expiry date is 2 years from production date and can be extended for extra 1 year after a successful testing of the physical and chemical index.
Packing
200L steel drum or 1000L IBC or per clients' request
Safety and handling
Skin Exposure:
In case of contact, immediately wash skin with soap and copious amounts of water. If irritation persists, call a physician.
Eye Exposure:
In case of contact with eyes, flush with copious amounts of water for at least 15 minutes. Assure adequate flushing by separating the eyelids with fingers.
If irritation persists, call a physician.
Inhalation Exposure:
If inhaled, remove to fresh air. If necessary, give oxygen. Call a physician.
Oral Exposure:
If swallowed, immediately wash out mouth with water provided person is conscious. Call a physician.
Hot Tags: Acid Corrosion Inhibitor 140℃, China Acid Corrosion Inhibitor 140℃ manufacturers, suppliers, factory, corrosion inhibitor for air purifiers, corrosion inhibitor for seawater, corrosion inhibitor for brine, corrosion inhibitor for refineries, corrosion inhibitor for dishwashers, applicable to steel