General
Beyond ZX-L4-01 Lubricant Viscosity Modifier (Viscosity Index Improver) is a premium star Viscosity Modifier concentrate, made from a hydrogenated styrene-diene based solid, Beyond Lubricant Viscosity Modifier (Viscosity Index Improver) ZX-L4-02 (solid format). It is dissolved in a API Group III diluent oil. This high quality product is designed for use in top tier, multigrade oils meeting stringent performance requirements and improved fuel economy.
Composition
It is made from hydrogennated styrene-diene.
Product properties
|
Items |
Value |
Unit |
Method |
|
Appearance |
Clear liquid |
ITM 50-042 |
|
|
Color |
3.0 Maximum |
ASTM D1500 |
|
|
Density @15℃, kg/m³ |
837.6 |
kg/m³ |
ASTM D4052 |
|
Density @60℉, Ib/gal |
6.99 |
Ib/USG |
ASTM D4052 |
|
Flash Point Deg ℃ |
216 |
℃ |
ASTM D93 |
|
Kinematic Viscosity @ 100℃ |
259 |
cST |
ASTM D445 |
|
Kinematic Viscosity @ 40℃ |
3159 |
cST |
ASTM D445 |
|
Kinematic Viscosity @ 60℃ |
1387 |
cST |
ASTM D445 |
|
Kinematic Viscosity @ 80℃ |
701 |
cST |
ASTM D445 |
Performance
Beyond Lubricant Viscosity Modifier (Viscosity Index Improver) ZX-L4-01 has super shear stability performance, low temperature performance, optimal contribution to high temperature viscosity, as well as improved fuel economy performance when dissolved in API Group III oil, particularly when used with Beyond DI package technology to formulate lubricants.
Handling/Precautions
Localized high temperatures should be avoided during heating, especially when product cannot be agitated. Electrical, steam or hot oil heating systems with a self-limiting maximum temperature not exceeding 120℃/250℉ (e.g. low pressure steam at 2 bar or 3 psig) are recommended. For safety reasons free water mu be avoided when product is handled above 95℃. Free water is always detrimental to product quality.
Min load/Unload temperature: 80℃/176℉
Max load/Unload temperature: 115℃/239℉
Viscosity @Min load/Unload temperature: 554 cST
Viscosity @Max load/Unload temperature: 159 cST
Maximum storage temperature: 80℃/176℉
Do not reheat above: 100℃/212℉
Package
200L steel drum or 1000L IBC or per clients' request.
Safety and handling
Wear appropriate personal protective equipment when responding to spills. Avoid generation of dust. Take precautionary measures against static discharges, earth/ ground all equipment. Do not breathe dust. Use local exhaust over processing area. Considering the risks of electrostatic discharges handling the products in potentially flammable atmospheres should be evaluated carefully. Suitable precautions should be taken at all times especially when emptying bags or other packaging.
For detailed data please refer to the relevant MSDS.
Hot Tags: viscosity modifier, China viscosity modifier manufacturers, suppliers, factory